Infrastructure Settings


This setting specifies the IP Address of the EVS video server to be controlled by LSM-VIA.

Description |
Up to 4 operators may work independently on the same server from their respective LSM-VIA workstation and remote panel (multi-operator mode). This setting is used to set the number of operators working with the same EVS server. It must be the same on each workstation. Then, each operator must select his/her operator number thanks to the Operator Position parameter. See also section Multi-Operator Mode. |
Possible Values |
From 1 to 4. |
Default value |
1 |

Description |
When more than 1 operator has been set from the Total Number of LSM-VIA Connected to the Server parameter (multi-operator mode), this setting is used to select the operator number on each workstation. It must therefore be different on each workstation. See also section Multi-Operator Mode. Channels distribution: The number of available players on the server is divided by the number of operators. If there are more players than operators, the first operator(s) get(s) more players. The first operator receives the first player(s).
The selection of recorders per operator is done with the Operator Recorders parameter. The remote buttons will automatically be mapped appropriately. |
|||||||||
Possible Values |
Operator 1, Operator 2, Operator 3, Operator 4. |
|||||||||
Default value |
Operator 1. |

Description |
Allows to select the recorder channels the selected operator will be able to work with. |
Possible Values |
Recorder labels from A to L. Click the recorder buttons to select (highlight) the corresponding recorder channels.
The same recorders can be selected by several operators. The remote buttons will automatically be mapped appropriately. |
Default value |
No recorder selected. |


This setting specifies the IP Address of the machine hosting the Xsquare to be used for export purposes.

This field is used to enter the login of the VIA Xsquare user.

This field is used to enter the password of the VIA Xsquare user.

This button is used to check the connection withVIA Xsquare.
The result will be displayed in one of the following ways:
or


Description |
Allows the use of Dyvi macros from the Remote Panel. The Dyvi macros, if appropriately configured, will be available as functions to be mapped to Remote Shortcut buttons/keys. So, the operator will be able to trigger the Dyvi macros from the Remote Panel console or touchscreen. Up to 6 Dyvi macros can be used from LSM-VIA. |
||||||
Possible Values |
|
||||||
Default value |
No (cleared) |

This setting specifies the IP Address of the Dyvi switcher to be connected to LSM-VIA.
It is only displayed when the Enable Dyvi Macros parameter has been selected.